CytoTell绿
产品名称: CytoTell绿
英文名称: CytoTell Green
产品编号:
产品价格: null
产品产地: CytoTell绿
品牌商标: 美国
更新时间: null
使用范围:
北京方程生物科技有限公司
- 联系人 :
- 地址 : 北京市海淀区安宁庄西路15号
- 邮编 : 100080
- 所在区域 : 北京
- 电话 : 132****8551;153****6903 点击查看
- 传真 : 点击查看
- 邮箱 : bio_fc@163.com
Flow cytometry combined with fluorescence staining is a powerful tool to analyze heterogeneous cell populations. Among all the existing fluorescent dyes CFSE is the preferred cell proliferation indicator that is widely used for live cell analysis. However, there are a few severe problems associated with the use of CFSE for monitoring cell proliferation. 1). CFSE is highly toxic to cells. CFSE indiscriminately reacts with all amino groups, thus changes many critical intracellular protein functions (such as cell membrane GPCRs); 2). CFSE has slow response and is inconvenient to use. The CFSE fluorescence intensity of the 2nd generation cells is decreased more than 10 fold from the 1st generation. You would have to wait for another generation to start the cell proliferation analysis. 3). Medium removal is required. You would have to remove medium for cell analysis with a flow cytometer since CFSE reacts with medium components. CytoTell Green is developed to eliminate these limitations. It has distinct advantages over CFSE. 1). CytoTell Green has very minimal cytotoxicity since it does not react with proteins. It is well retained in cells since the probe is designed to minimize the MDR interaction that generally pumps many cell stains out cells; 2). CytoTell Green exhibits much faster response and is more convenient to use than CFSE. There is no fluorescence intensity gap between 1st and 2nd generation of cells. As cells divide, CytoTell Green is distributed equally between daughter cells that can be measured as successive halving of the fluorescence intensity of the dye; 3). There is no need to remove medium since CytoTell Green does not react with medium components; 4). CytoTell Green is more sensitive than CFSE. Up to 9 generations may be visualized; 5). CytoTell Green is much more stable than CFSE. CytoTell Green stock solution can be stored at room temperature for a few days. CytoTell Green can also be used for long term tracking of labeled cells. Analysis using two-parameter plots may provide better resolution of each generation, especially between undivided cells and the first generation. Cells labeled with Cell CytoTell Green may be fixed and permeabilized for analysis of intracellular targets using standard formaldehyde-containing fixatives and saponin-based permeabilization buffers. CytoTell Green has a peak excitation of 520 nm and can be excited by the blue (488 nm) laser line, making it compatible with FITC filter set.